Fire Alarm System Service
To ensure their reliability, fire alarm and detection systems must be inspected, tested, and maintained regularly. FireChoker Fire Protection, serving New Zealand will set up a service program for periodic testing, inspection, and maintenance that conforms to:
Fire Alarm Inspection, testing and survey
Our fire alarm inspection process includes:
Fire Alarm Maintenance in New Zealand
Maintenance of your fire alarm system is extremely important. When properly maintained your fire alarm system will provide early detection and warning to building occupants, helping to prevent disasters or fatalities from occurring. At FireChoker, our fire alarm technicians will maintain, inspect, test, or repair any specific fire alarm components, notification appliances, initiating devices, interfaces, zones, or circuits necessary to accomplish the goal of meeting or exceeding building and fire codes, insurance company requirements, and any other applicable entities keeping your fire alarm system properly operating.
At FireChoker NZ, our expert fire alarm inspection technicians’ goal is to make sure your fire alarm is fully functional so it will perform properly when needed in a time of emergency or to notify you of faulty devices in your building. We can inspect all brands of fire alarms, including:
Whatever your fire alarm inspection needs, go to the fire alarm inspection experts — call FireChoker NZ today!
To ensure their reliability, fire alarm and detection systems must be inspected, tested, and maintained regularly. FireChoker Fire Protection, serving New Zealand will set up a service program for periodic testing, inspection, and maintenance that conforms to:
- NZS 4512 & NFPA code requirements
- Local authorities having jurisdiction
- System manufacturer’s recommended inspection and maintenance requirements
- Required annual fire alarm system testing
Fire Alarm Inspection, testing and survey
Our fire alarm inspection process includes:
- Testing the control panel functions, including lamp and LED operation, fuse operation, interface equipment, and primary power.
- Testing smoke detectors by introducing approved aerosol into the smoke detector chamber or specific manufacturer recommended methods of performing the proper test, then verifying the proper signal was received at the alarm panel.
- Cleaning all smoke detectors tested with air brush.
- Testing manual pull stations through a full range of motion and verifying the proper signal was received at the alarm panel.
- Testing heat detectors with a heat gun and verifying proper alarm activation at the fire alarm control panel.
- Testing and inspecting all audible and visual devices to ensure that they are unobstructed, proper lights activate, and the sound level is above ambient noise levels.
- Random checking of circuit supervision to ensure fire alarm panel detects an open circuit.
- Load testing stand-by batteries and checking auxiliary functions such as door release and damper release.
- Testing battery charger.
- Verifying the fire alarm monitoring company received the appropriate signals.
- Testing remote mimic panel to verify it accurately portrays where the alarm exists in the protected premises.
- Testing duct detectors and ensuring proper unit shutdown, if applicable.
- Checking any auxiliary devices that may exist and are listed on the equipment list included in this contract (door holder release, dampers, etc.)
- NFPA required sensitivity testing of smoke detectors, performed initially and every other year thereafter. This service is not included in this contract unless specifically stated and for an additional fee.
Fire Alarm Maintenance in New Zealand
Maintenance of your fire alarm system is extremely important. When properly maintained your fire alarm system will provide early detection and warning to building occupants, helping to prevent disasters or fatalities from occurring. At FireChoker, our fire alarm technicians will maintain, inspect, test, or repair any specific fire alarm components, notification appliances, initiating devices, interfaces, zones, or circuits necessary to accomplish the goal of meeting or exceeding building and fire codes, insurance company requirements, and any other applicable entities keeping your fire alarm system properly operating.
At FireChoker NZ, our expert fire alarm inspection technicians’ goal is to make sure your fire alarm is fully functional so it will perform properly when needed in a time of emergency or to notify you of faulty devices in your building. We can inspect all brands of fire alarms, including:
- Notifier
- Pertronic
- Tyco MX
- Siemens
- Ampac
- Kidde
- Edwards/EST
- Brooks/Fire-tracker
Whatever your fire alarm inspection needs, go to the fire alarm inspection experts — call FireChoker NZ today!